Received 11 April 2006/ Returned for modification 26 May 2006/ Accepted 14 July 2006
|
|
|---|
7). Thus, we herein suggest a new simple, effective, and efficient pH-controlled FRET-based antimicrobial peptide screening method applicable to high-throughput screening of candidate peptide libraries. |
|
|---|
Owing to the potential superiority of AMPs as antibiotics, many researchers have sought to screen potential candidate peptides from various types of organisms. However, the traditional screening methods used to test AMP candidates have proven time consuming and laborious, limiting the effectiveness of these studies. To overcome these limitations, we here introduce a novel fluorescence resonance energy transfer (FRET)-based assay for rapid and high-throughput screening of AMPs. In general, FRET is the distance-dependent transfer of energy from a donor fluorophore to an acceptor fluorophore (12). For this process to occur, the distance between two fluorophores should be 2 to 6 nm, and the emission spectrum of the donor must overlap with the excitation spectrum of the acceptor by more than 30% (15). These requirements have been used to develop FRET-based fluorescent biosensors, in which ionic distributions or kinetics are assessed with regard to the alteration of the distance between two fluorescent proteins by specific ions, chemicals, or other compounds (2, 10). However, for employment of distance-based FRET as an AMP screening system, its major limitation will be a difficulty in obtaining a sufficient concentration gradient of ions or chemicals between the areas inside and outside of cells.
The novel technique presented herein takes advantage of a previous study showing that the stabilities of enhanced green fluorescent protein mutants, such as enhanced cyan fluorescent protein (ECFP) and enhanced yellow fluorescent protein (EYFP), were pH dependent and that while ECFP and EYFP maintained their native fluorescence signatures at a physiologically normal pH of 7.0, the stability of EYFP, but not of ECFP, was significantly decreased at a reduced pH (9). In particular, we based our method on the hypothesis that the FRET efficiency of an ECFP-EYFP fusion protein expressed in Escherichia coli would differ based on pH and that providing a reduced-pH extracellular environment would allow us to distinguish between extracellular molecules released by disrupted E. coli cells and molecules retained in the intracellular environment (pH
7).
|
|
|---|
![]() View larger version (15K): [in a new window] |
FIG. 1. Gene map of recombinant plasmid pCPY-S. Plasmid pET22b(+) was used as a parent vector. Abbreviations: ecfp, enhanced cyan fluorescent protein gene; eyfp, enhanced yellow fluorescent protein gene; Term, termination sequence; Ampr, ampicillin resistance gene; lacI, overexpressed lac repressor gene; ori, replication origin.
|
1 x 109 recombinant E. coli cells expressing intracellular ECFP-EYFP were completely disrupted by sonication in phosphate-buffered saline (PBS) buffers of various pH values (8.5, 8.0, 7.5, 7.0, 6.5, 6.0, 5.5, and 5.0). The cell lysates were centrifuged, and the emission spectra of the supernatant were scanned using a fluorescence spectrophotometer (Shimadzu), with excitation at 433 nm.
Antimicrobial assay using pH-controlled FRET.
The procedure consisted of two steps, an antimicrobial reaction at pH 7.0 followed by equilibration at pH 6.0. Equilibration should be allowed to proceed for no more than 20 min; longer equilibration times yielded huge deviations in the results, due to additional ECFP-EYFP expression by living cells during that time (data not shown). For experiments,
1 x 109 ECFP-EYFP-expressing cells were suspended in 20 µl of PBS buffer containing 0, 0.25, 0.50, 0.75, or 1 nM bovine serum albumin (BSA) (Sigma), Hal 18 (a gift from I.-H. Lee of Hoseo University), or magainin II (Sigma). The antimicrobial reaction was allowed to proceed for 30 min. After that time, each sample was equilibrated in 2 ml of PBS buffer (pH 6.0) for 20 min, and the emission spectrum and fluorescence intensity of ECFP at 475 nm and EYFP at 527 nm were measured with excitation at 433 nm using a fluorescence spectrophotometer. pH-controlled FRET assays were also performed for other nonpeptide compounds (lysozyme [Sigma], sodium dodecyl sulfate [SDS] [Kanto chemical], and kanamycin [Sigma]). For experiments involving the fluorescence microplate reader system, the cell number was reduced to
1 x 108, but antimicrobial reactions were performed as described above. For equilibration, 180 µl of PBS buffer (pH 5.84) was added to each sample, adjusting the final pH to 6.0. The fluorescence intensities at 475 and 527 nm were measured with excitation at 433 nm, using a fluorescence microplate reader (Molecular Devices).
Antimicrobial assays using colony counting and MIC. For the colony counting assay, noninduced recombinant E. coli cells (6 x 106) were subjected to antimicrobial reactions as described above. The samples were then serially diluted, and the dilutions were incubated on agar plates at 37°C for 12 h. Antimicrobial activity was calculated with regard to the number of CFU remaining in each sample. For the MIC assay, noninduced recombinant E. coli cells were diluted to approximately 1 x 105 CFU/ml. Cells (90 µl) and peptide (10 µl) were mixed and incubated overnight at 37°C. The MIC was determined as the lowest concentration which inhibited bacterial growth completely.
|
|
|---|
![]() View larger version (43K): [in a new window] |
FIG. 2. Basic concept of the pH-controlled FRET assay system (A) and emission spectra of ECFP-EYFP fusion proteins at different pHs (B). The emission spectra for ECFP-EYFP excited at 433 nm were monitored in buffers ranging from pH 5.0 to 8.5.
|
Quantification of antimicrobial activities with yellow/cyan fluorescence intensity ratio. We demonstrated the application of pH-based FRET for quantitative assay of AMPs by investigating the FRET spectrum and Y/C ratio, which is the FI ratio between EYFP at 527 nm and ECFP at 475 nm when emission is triggered from ECFP-EYFP fusion proteins by excitation at 433 nm, for various concentrations of three different proteins: BSA (negative control) and the AMPs halocidin 18-mer (Hal 18) (8, 14) and magainin II (16). Although antimicrobial activity is generally evaluated based on µg/ml amounts, we utilized the molar concentration in these experiments in an effort to equalize the number of effective molecules, because BSA has a much larger molecular mass (67 kDa) than Hal 18 (1.93 kDa) and magainin II (2.43 kDa). In the case of cells treated with BSA, no changes were observed in the spectrum at 527 nm (Fig. 3A) or the Y/C ratio plot (Fig. 3D), demonstrating that the negative control had no antimicrobial activity against E. coli, i.e., BSA did not alter the cellular entrapment of ECFP-EYFP. In contrast, treatment of cells with Hal 18 and magainin II dose dependently decreased emission at 527 nm (Fig. 3B and C) and dose dependently increased antimicrobial activity, as shown in the Y/C ratio plots (Fig. 3E and F). The linear slopes of these plots reflected the antimicrobial activity, indicating that this method could be used to quantitatively assess the antimicrobial activities of specific or unknown concentrations of target peptides. These findings strongly suggest that our novel pH-based FRET technique should be applicable for quantitative and/or comparative assay of AMPs. We also tested our pH-controlled FRET assay system using nonpeptide compounds; the enzyme lysozyme and the detergent SDS, which disrupt the bacterial membrane, and the chemical antibiotic kanamycin, which inhibits protein synthesis through binding to ribosome (Fig. 4). In both the case of lysozyme and of SDS, Y/C ratios were dose dependently decreased, that is, a tendency identical to that in the case of the antimicrobial peptide. In contrast, kanamycin did not show any changes of Y/C ratio. Therefore, these results demonstrate that our FRET-based assay system is specifically applicable for all cases of bacterial membrane disruption.
![]() View larger version (35K): [in a new window] |
FIG. 3. Antimicrobial activity assays using pH-controlled FRET with a fluorescence spectrophotometer. The emission spectra for samples treated with various concentrations of (A) BSA, (B) Hal 18, or (C) magainin II were scanned following excitation at 433 nm. The Y/C ratios for (D) BSA, (E) Hal 18, or (F) magainin II were plotted according to the applied amount of each agent. Each measured value and error bar represent the mean for three independent experiments and the standard deviation.
|
![]() View larger version (33K): [in a new window] |
FIG. 4. pH-controlled FRET assays with a fluorescence spectrophotometer for other nonpeptide compounds. The emission spectra for samples treated with various concentrations of (A) lysozyme, (B) SDS, or (C) kanamycin were scanned following excitation at 433 nm. The Y/C ratios for (D) lysozyme, (E) SDS, or (F) kanamycin were plotted according to the applied amount of each agent. Each measured value and error bar represents the mean for three independent experiments and the standard deviation.
|
![]() View larger version (8K): [in a new window] |
FIG. 5. Conventional colony counting assay for antimicrobial activity (A) and direct comparison between pH-controlled FRET and colony counting (B). The two methods and their bidirectional error bars were compared by combining Fig. 3A and 2F. Each measured value and error bar represent the mean for three independent experiments and the standard deviation.
|
1.6 and use this to compensate for variations in the absolute FI values. If we theoretically assume that a specific concentration of AMP can destroy 50 cells out of an initial cell number of 100, we can estimate that a 10% increase in the initial cell number could cause a 10% variation in the FI of a single-fluorescent-protein system but only a 4.5% variation in a two-fluorescent-protein system.
Employment of microplate reader system for high-throughput antimicrobial assay.
Recently, numerous groups have sought not only to identify new AMPs from various species but also to find artificially substituted peptide analogs capable of conferring improved activity (1, 7). One major limitation of substitution studies has been the enormous breadth of combinatorial peptide libraries and requirement of a high-throughput screening technique for antimicrobial activity. Thus, we tested whether our new pH-controlled FRET assay could be applied using a fluorescence microplate reader system as a first step towards scaling up to high-throughput screening applications. Indeed, our method could be easily applied using a microplate reader (Fig. 6A), which offered the important advantage of simultaneous excitation and detection. This resulted in an identical equilibration time for every sample, possibly reducing errors introduced by between-sample differences in the measuring interval. Furthermore, the microplate reader system allowed us to reduce the initial cell number by about 1/10 of the original requirement, providing higher sensitivity by increasing the relative peptide concentration per cell. We found that application of pH-controlled FRET with the microplate reader system yielded larger Y/C ratio reductions for both of the test AMPs. This allowed us to compare the antimicrobial activities of magainin II and Hal 18 (Fig. 6B), which we had been unable to manage using the fluorescence spectrophotometer (see Fig. 3). Our results revealed that magainin II had a higher antimicrobial activity than Hal 18; this finding was subsequently confirmed by the colony-counting method (data not shown). In the case of the MIC assay, magainin II had a slightly lower MIC than Hal 18 even though their values are similar (
5 µM). Finally, we found that the Y/C ratio for magainin II reached the saturation value (
0.8) at an amount of
0.75 nmol in the microplate reader system, suggesting that it might be possible to reduce the dose of treated peptides while still maintaining the Y/C ratio over the saturation value at pH 6.0 (which is required for accurate assay). However, although the initial cell number was reduced by 1/10 (from 1 x 109 to 1 x 108), we did not see a similar decrease in the amount of AMPs required for saturation of the Y/C ratio. This may indicate that a basal peptide concentration may be required for antimicrobial reactions against a specific number of cells.
![]() View larger version (27K): [in a new window] |
FIG. 6. Antimicrobial activity assays using pH-controlled FRET with a fluorescence microplate reader. (A) Overview of the high-throughput assay system. (B) Y/C ratios for BSA, Hal 18, and magainin II were plotted according to the applied amounts. Each measured value and error bar represent the mean for three independent experiments and the standard deviation.
|
We thank In Hee Lee (Hoseo University, Korea) for providing chemically synthesized Hal 18.
|
|
|---|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||