Ruth Ben-Ari Institute of Clinical Immunology, Kaplan Medical Center, Rehovot 76100, Israel,1 Cupron, Inc., POB 10973, Greensboro, NC 27404,2 Institute for Antiviral Research, Utah State University, Logan, Utah 84322-5600,3 Department of Virology, Faculty of Health Sciences, Soroka Academic Medical Center, Beer-Sheva 84105, Israel4
Received 28 January 2007/ Returned for modification 15 March 2007/ Accepted 24 April 2007
|
|
|---|
|
|
|---|
Copper has potent virucidal properties, and copper's neutralization of infectious bronchitis virus, poliovirus, human immunodeficiency virus type 1 (HIV-1), and other enveloped or nonenveloped single- or double-stranded DNA or RNA viruses has been reported (3).
Recently, a durable platform technology was developed that introduces copper oxide into cotton fibers, latex, and other polymeric materials (2), endowing them with potent broad-spectrum antibacterial and antifungal properties (4). Based on the wide-spectrum antiviral potency of copper (3), we hypothesized that passing suspensions spiked with viruses through filters containing copper oxide-impregnated fibers would result in the neutralization of these viruses.
We designed filters with a radius of 2.5 cm containing a 2-cm-thick upper layer of 500 mg of nonwoven polypropylene fibers impregnated with 5% (wt/wt) copper oxide particles (Fig. 1) and a 0.2-cm bottom layer of 100 mg of nonwoven activated carbon fibers. The bottom layer was used to entrap any possible copper particulates or copper ions that might have been released from the first layer during filtration. Filters with polypropylene fibers that were not impregnated with copper oxide, served as negative controls. Clarified cell supernatant fluids containing 105 to 108 50% cell culture infectious doses (CCID50)/ml served as viral inocula. The capacity of the filters to deactivate viruses in physiologically relevant filterable solutions was determined with HIV-1 by using human plasma and human breast milk. All other viruses were diluted 1:10 in appropriate culture medium (minimal essential medium, Dulbecco's modified Eagle's medium, or RPMI 1640) without serum. Ten milliliters of each viral inoculum was put in a syringe attached to a filter and passed through the dry filter by manually applying moderate pressure to the syringe plunger. The retention time of the media within the filter was approximately 2 min. With experiments involving HIV-1, the flow rate was adjusted to 0.25 ml/cm2/min by using a peristaltic pump. The filtrate was collected in sterile tubes and subjected to multiple 4- or 10-fold dilutions in appropriate media containing serum. Each dilution was then added to appropriate target cells (Table 1) in 96-well microplates using three replicate wells per dilution. After 3 to 4 days of culture, the infectious viral titers for vaccinia virus were determined by using a plaque assay and, for all other viruses, by using a cytopathic-effect assay. The titer was calculated by using the Reed-Muench end point dilution method (7). An unfiltered sample from each original clarified viral stock was also titered in parallel. Ten milliliters of culture medium, without virus, passed through the filter was used as a negative control for antiviral activity. Overall, six filters were used for each virus, three containing copper and three not containing copper.
![]() View larger version (41K): [in a new window] |
FIG. 1. (a) Sketch of copper oxide-containing filter. (b and c) Scanning electronic microscope pictures of the copper oxide-impregnated polypropylene fibers. (d) X-ray analysis of the copper oxide-impregnated polypropylene fibers, showing the copper content.
|
|
View this table: [in a new window] |
TABLE 1. Reduction of infectious viral titers by copper oxide-containing filters
|
![]() View larger version (6K): [in a new window] |
FIG. 2. Effect of flow rate on HIV-1 deactivation. Ten milliliters of human plasma containing 2 x 105 CCID50 of HIV-1 was added at room temperature to copper oxide-containing filters or to control filters containing no copper oxide. The plasma was eluted from the filters via a peristaltic pump at flow rates of 0.25 ml/cm2/min to 0.025 ml/cm2/min. The eluates were then subjected to sequential fourfold dilutions and added to MT2 cells. The CCID50 was determined after 4 days of culture as previously described (2). The y axis shows the difference between the log10 CCID50s obtained by the eluates of the control filters minus the log10 CCID50s obtained by the eluates of the copper oxide-containing filters. The average and standard deviation of triplicate experiments for each flow rate are shown. *, undetectable residual virus.
|
Excess copper in humans at the level that is expected to be leached out into the milk, blood, or plasma as it passes through the copper filters (1 to 20 ppm) (data not shown) is not toxic. This represents only a minor perturbation to the normal serum copper levels in blood, which range from approximately 80 to 160 µg/dl (1, 8). Obviously, the effect of the copper filters on the important components found in breast milk, such as the protecting immunoglobulins, or those components found in blood, such as coagulation factors, should be thoroughly studied before implementing this technology. Preliminary data indicate that the copper oxide filters do not cause damage to red blood cells or coagulation factors found in plasma.
For most applications, if this technology is to be useful, complete neutralization of viruses in a given solution should be achieved. Depending on the solution composition and volume and the viruses that may contaminate these solutions, appropriate filters will have to be developed. Clearly, larger volumes of the active copper oxide-impregnated fibers are needed. The retention time of the solution in the filter should be increased by decreasing the flow rate and/or increasing the filter volume. This copper-based technology may, therefore, represent a novel and inexpensive means to quickly deactivate viruses in contaminated liquids.
Published ahead of print on 30 April 2007. ![]()